AI COMPUTE INFRASTRUCTURE

Turnkey NVIDIA B300
datacenter campuses

From dedicated 110kV grid substations to stainless steel Direct Liquid Cooling (DLC) loops: KOTA Orbit executes multi-megawatt facilities for hyperscale frontier AI.

INFRASTRUCTURE PILLARS

Megawatt Substation Engineering

Dedicated high-voltage grid connections with N+1 redundant dry-type transformers, lithium-iron-phosphate UPS and microgrid integration.

  • · 10 MW to 120 MW scalability
  • · 99.999% tier-IV utility reliability
  • · Direct renewable power integration

Direct-to-Chip Liquid Cooling

Closed stainless steel distribution manifolds route treated water at 35°C directly to B300 Blackwell Ultra plates, enabling 100% free cooling.

  • · PUE 1.12 to 1.14 annual average
  • · Up to 135 kW per server rack
  • · Zero evaporative water waste

Quantum-X800 InfiniBand

Full-bisection 800 Gb/s bandwidth per GPU node with non-blocking dragonfly topologies for distributed LLM training without communication bottlenecks.

  • · 800 Gb/s InfiniBand & Spectrum-X
  • · Sub-100ns packet latency
  • · Hardware SHARP in-network reduce

MODULARE KI-INFRASTRUKTUR

Schlüsselfertige modulare KI-Container-Rechenzentren

Vorgefertigte 20ft- und 40ft-Container mit flüssigkeitsgekühlten NVIDIA B300 Servern. Weltweit in wenigen Wochen betriebsbereit.

40ft AI Container Pod
EXTERIOR ARCHITECTURE

40ft AI Container Pod

Turnkey heavy-gauge steel modular pod with weatherized external dry coolers and CDUs. Matte black industrial finish with KOTA ORBIT precision branding.

HIGH-DENSITY MODULARITY

18 Racks / 40ft Pod

Bis zu 2,4 MW Rechenkapazität pro Container mit Hochstromschienen.

  • 20ft (8 Racks, ~1.0 MW) & 40ft (18 Racks, 2.4 MW)
  • Up to 135 kW per server rack
  • Integrated busway & clean-agent fire suppression
THERMAL EXCELLENCE

Geschlossene DLC-Kühlung

Direct-to-Chip Edelstahlverteiler mit externen Trockenkühlern. PUE 1.12.

  • 35°C warm-water supply (100% free cooling)
  • PUE 1.12 annual average
  • N+1 redundancy on internal CDUs
SPEED TO MARKET

Plug & Play Fabrik

Stapelbare Container für 10 MW bis über 50 MW KI-Rechenfabriken nach Bedarf.

  • 4 to 8 weeks global delivery & hookup
  • Avoids 24–36 month traditional civil delays
  • Full EcoBlox/MDC architectural parity

KOTA ORBIT Modular Datacenter Engineering

KOTA Orbit provides full engineering parity with modular containerized standards (EcoBlox architecture). From single 20ft edge pods to multi-megawatt campus grids, every unit is pre-assembled, factory-tested with B300 Blackwell Ultra servers, and delivered turnkey.

SUBSEA-RECHENINFRASTRUKTUR

Unterwasser-KI-Pods: Hyperscale-Rechenleistung auf dem Meeresgrund

Hermetisch versiegelte Unterwasser-Druckkapseln mit Tiefsee-Kühlung und inerter Stickstoffatmosphäre. PUE 1.05 und 8-fach höhere Hardware-Zuverlässigkeit ohne Frischwasser.

Seabed Pod Architecture
DEEP OCEAN DEPLOYMENT (35M DEPTH)

Seabed Pod Architecture

Hermetically sealed underwater pressure capsule resting on the continental shelf. Surrounded by natural 4°C to 12°C seawater for continuous, chiller-free convective cooling.

DESIGN PUE
1.05

Direct titanium marine heat exchangers dissipate 100% of GPU thermal load into ambient seawater without chillers or cooling towers.

FRESHWATER CONSUMPTION
0.00 L

Zero freshwater consumed. Eliminates the millions of liters of potable water lost annually to evaporative cooling on land.

HARDWARE RELIABILITY
8x Lower Failures

Hermetic dry Nitrogen (N2) atmosphere with zero oxygen or moisture prevents copper corrosion and thermal solder fatigue.

POWER SOURCE
100% Offshore

Direct connection to offshore wind turbines and tidal arrays via armored umbilical power cables, achieving true net-zero compute.

Engineering Comparison: Subsea Pods vs. Terrestrial Datacenters

Architecture ParameterKOTA ORBIT Subsea PodTraditional Hyperscale Facility
Power Usage Effectiveness (PUE)1.05 – 1.071.35 – 1.60
Water Consumption (WUE)0.00 L / kWh (Zero Potable Water)1.80 L / kWh (Evaporative Towers)
Atmosphere & EnvironmentDry Nitrogen (N2), 0% Oxygen, 0% HumidityAmbient Air, Oxygen, Dust, Humidity
Server Component MTBF (Failure Rate)8x Lower Component FailureStandard Baseline Failure Rate
Deployment Timeline< 90 Days Marine Turnkey24 – 36 Months Civil Construction
Land Acquisition & Zoning0 m² Real Estate FootprintHigh Coastal Land Costs & Permits
CAMPUS SIZING TOOL

NVIDIA B300 Datacenter Configurator

Simulate campus capacity, B300 rack density, direct liquid cooling and substation load.

ARCHITECTURE: BLACKWELL ULTRA NVL
40 MW
10 MW (Edge Campus)40 MW (Standard)120 MW (Gigawatt Scale)
120 kW / Rack
80 kW (Standard DLC)120 kW (B300 High Density)135 kW (Max Peak)
1.14
1.10 (Free Cooling)1.14 (KOTA Orbit Standard)1.25 (Hybrid)
Direct-to-chip stainless steel manifolds dissipate > 90% of heat into liquid loops, enabling annual free cooling without mechanical chillers.
AUDITED SPECIFICATION & HARDWARE TOPOLOGY
B300 GPU COUNT
21,312
Blackwell Ultra Units
DLC RACKS
333
120 kW Server Schränke
AI COMPUTE POWER
319.7 EF
ExaFLOPS (FP4 Sparse)
GRID DRAW
45.6 MW
Campus Total Load
DLC FLOW RATE
11,200
Liters / min Loop
BUILD TIMELINE
16 Mo.
Turnkey Commissioning
Need detailed single-line electrical diagrams or site allocations?
Request Feasibility Study

EPC TURNKEY EXECUTION

End-to-end delivery from site feasibility to power-on

PHASE 01

Feasibility & Power

Grid interconnection agreements, site permitting and environmental water assessments.

PHASE 02

Civil & Substation

Constructing reinforced hardened facilities, transformer bays and exterior cooling yards.

PHASE 03

Mechanical & Fit-Out

Installing CDUs, primary stainless piping loops, isolated busways and clean agent fire suppression.

PHASE 04

B300 Racks & Handover

White space integration of NVIDIA B300 racks, InfiniBand fabric commissioning and tier certification.